Electric Cables from FCT

FCT Fabbrica Trentina Conduttori Sud Tirol Kabelwerke

This article describes a range of electric power cables and telephone cables available from FCT.

Indoor Telephone Cable

J-YY Single-wired conductor of plain copper wire, PVC-based core insulation, fur cores twisted to star quad, core colours according to VDE 0815, PVC-based outer scheath, RAL 7032 J-Y (ST) Y Like J-YY...BD but cores are twisted in pairs, cable core covered by a static screen of aluminium-clad plastic wire with copper conductor, PVC-based outer sheath RAL 7032.

Indoor Telephone Cables

BMD brandmeldekabel is the same cable but with red PVC sheath, request for alarm system.

Fireproof Cables Eurosafe 180

Fireproof Cables Eurosafe 180

FTC can cater to clients' needs in producing security cables which are fire resistant for use in firefighting plants, both with special special ceramised Silicon isulation, with or without alluminium foil and with LSZH outer sheath. These cables are produced to be able to work between 30 and 180 minutes in fire situation. This cable is available from 0,5 to 2,5 sqmm and from 2 to 5 cores

Section
( mm2 )
Max electrical
resistance to 20°
Strand and
wire diameter
Insulation
diam. (mm)
Outer
diameter
2 x 1.0018.01 Ohm/Km1 x 1.132.6 ± 0.18,2 ± 0.2
3 x 1.0018.01 Ohm/Km1 x 1.132.6 ± 0.19,2 ± 0.2
4 x 1.0018.01 Ohm/Km1 x 1.132.6 ± 0.110,2 ± 0.2
2 x 1.5012.01 Ohm/Km1 x 1.382.8 ± 0.18,6 ± 0.2
3 x 1.5012.01 Ohm/Km1 x 1.382.8 ± 0.19,6 ± 0.2
4 x 1.5012.01 Ohm/Km1 x 1.382.8 ± 0.110,4 ± 0.2
2 x 2.507.41 Ohm/Km7 x 0,673.4 ± 0.110,6 ± 0.2
3 x 2.507.41 Ohm/Km7 x 0,673.4 ± 0.111,6 ± 0.2
4 x 2.507.41 Ohm/Km7 x 0,673.4 ± 0.112,6 ± 0.2

Data Telephone Fire Resistants Cables Eurosafe E30 / E60

Data Telephone Fire Resistants Cables Eurosafe E30 / E60

  • Fire resistant EN 1363 -1 Din 4102 -12
  • Halogen Free
  • Fire retardant ( VDE 0472 Part 804-C, BS 4066 Part 3 (NMV 1,5), IEC 332-3 cat.CF)
  • Low smoke and fume
  • No emission of corrosive and toxic gases
  • VDE 0815
Conductor Diameter:- 0,8 mm0,6 mm
loop resistance:
insulation resistance at 20° C max:
Nominal capacitance at 800 Hz:
Capacitance unbalance between pairs at 800 Hz
k1 max:
k9 - K12 max:
130 mm73,2 mm
100 M km
120 nF/km

300 pF/500m
100 pF/500m

 

Number of pairs and
conductor diam. ( mm )
Calorific
patential kWh/m
Overall diam.
approx. mm
Copper
weight (mm)
Weight of cable
approx. Kg/km
1 x 2 x 0,6
2 x 2 x 0,6
3 x 2 x 0,6
5 x 2 x 0,6
10 x 2 x 0,6
1 x 2 x 0,8
2 x 2 x 0,8
3 x 2 x 0,8
5 x 2 x 0,8
10 x 2 x 0,8
0,18
0,30
0,35
0,48
0,74
0,24
0,41
0,50
0,69
0,11
6,3
9,0
9,4
11,0
13,6
7,4
10,9
11,5
13,5
17,0
14
25
37
59
116
25
45
65
106
206
30
35
50
60
70
160
190
240
285
360


Power Cables and Special Cables

Power Cables and Special Cables

FTC can supply the Security Market with a range of complementary cables used in installations.
Available version shielded and unshielded

Power Cables Power Cables

 

RSS