Latest Information on Control Cables from FCT.
YSLY - JZ PVC - Control cable with numbered cores. VDE Reg. Nr. 7616
YSLY - CY - JZ PVC - Insulated shielded control cable with interm. sheath. VDE Reg. Nr 7616
YSL - CY-JZ PVC - Insulated shielded control cable without intermediate sheath.
FRH2R PVC - Shielded control cable flame retardant, without intermediate sheath.
YSLY - SY-JZ PVC - Armoured control cable with intermediate sheath.
LIYCY - DIN Data control shielded cable with coloured cores DIN 47100 ( from 0.14 mm2 )
LIYCY - TP - DIN Data control cable as a.m. with twisted cores ( from 0.14 mm2 )
LIYCY - CY - DIN Data control cable as a.m. with shielded twisted cores ( from 0.14 mm2 )
LIYCY - BP - DIN Data control cable as a.m. with shielded twisted cores without total shield ( from 0.14 mm2 )
LIYY - DIN Unshielded Data control cable with coloured cores DIN 47100 ( from 0.14 mm2 )
For more information Click Here
| YSLY - JZ / OZ | |||
| Minimum bending radius for Flexing: 15 x cable diameter Static: 4 x cable diameter Temperatur range Flexing: - 5 °C to + 70 °C Static: - 30 °C to + 70 °C | Nominal Voltage: Uo/U: £1,5 mm2 / 300/500 V ³ 2,5 mm2 / 450/750 V in case of protected installation: 300/1000 V ( £1,5 mm2 ) Test Voltage: 4000 V Insulation: Specific insulation resistance: >20 G Wx cm | Conductor stranding: fine wire to VDE 0295 class 5 /IEC228CI.5 Core ident code: VDE-colour code: or black with number ( VDE 0293 ) Protective conductor: G = green / yellow X = without | Specification: Colours Cores in accordance with VDE 0245/0281 Sheath in accordance with VDE 0245/0281 Numbers Grey: Approved VDE Reg. Nr. 7616 |
![]()
| YSLY CY - JZ / OZ | |||
| Minimum bending radius for Flexing: 15 x cable diameter Static: 4 x cable diameter Temperatur range Flexing: - 5 °C to + 70 °C Static: - 30 °C to + 70 °C | Nominal Voltage: Uo/U: 300/500 V Test Voltage: 4000 V Insulation: Specific insulation resistance: >20 G Wx cm | Conductor stranding: fine wire to VDE 0295 class 5 / IEC228CI.5 Core ident code: or black with number ( VDE 0293 ) Protective conductor: G = GNYE - X = without | Specification: Colours Cores in accordance with VDE 0245/0281 Sheath in accordance with VDE 0245/0281 Numbers Grey: Approved VDE Reg. Nr. 7616 |
![]()
| YSLY SY - JZ / OZ | |||
| Minimum bending radius for Flexing: 20 x cable diameter Static: 6 x cable diameter Temperatur range Static: - 30 °C to + 70 °C | Nominal Voltage: Uo/U: 300/500 V Test Voltage: 4000 V Insulation: Specific insulation resistance: >20 G Wx cm | Conductor stranding: fine wire to VDE 0295 class 5 / IEC228CI.5 Core ident code: up to 5 cores: VDE-colour code | Protective conductor: G = GNYE - X = without Cores in accordance with: VDE 0295 Sheath in accordance with: VDE 0245/0281 |
![]()
| LIYY | |||
| Minimum bending radius for Flexing: 15 x cable diameter Temperatur range Flexing: - 5 °C to + 70 °C Static: - 30 °C to + 70 °C | Peak working Voltage: 250 V ( not for purposes of power / high voltage current Test Voltage: 1200 V Insulation: Specific insulation resistance: >20 G Wx cm | Conductor stranding: strands, fine wire 0,34 mm2 , 7-wire Core ident code: DIN 47100, without colour repetition | Mutual capacitance: C/C approx 120 nF / km Inductance: approx. 0,65 mH/km In reference to: VDE Specification: VDE 0812 |
![]()
| YSL CY | |||
| Minimum bending radius for Flexing: 15 x cable diameter Solitary: 6 x cable diameter Temperatur range Static: - 30 °C to + 70 °C | Peak working Voltage: 250 V ( not for purposes of power / high voltage current Test Voltage: 1200 V Insulation: Specific insulation resistance: >20 G Wx cm | Conductor stranding: strands, fine wire 0,34 mm2 , 7-wire Core ident code: DIN 47100 | Mutual capacitance: C/C approx 120 nF / km C/C approx 160 nF/ km Inductance: approx. 0,65 mH/km In reference to: VDE Specification: VDE 0812 |
![]()